Fluke i30s AC/DC Current Clamp
4,336.65SAR
4,336.65SAR
Ex Tax: 3,771.00SAR
The i30s current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.
Electrical specifications Specified current range 30 mA to 30 A DC, 30 mA to 20 A AC rms Usable current range 5 mA to 30 A DC, 30 mA to 20 A AC rms Crest factor 1.4 in Output sensitivity 100 mV/A Accuracy (at +25°C) ±1% of reading ±2 mA Resolution ±1 mA Load impedance > 100 kΩ Conductor position sensitivity ±1% relative to center reading Frequency range DC to 100 kHz (-0.5 dB) Phase shift below 1 kHz < 2° Temperature coefficient ±0.01% of reading / °C Power supply 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator Working voltage (see Safety Standards section) 300 V AC rms or DC General Specifications Maximum conductor size 19 mm diameter Output connection Safety BNC connector, supplied with safety 4 mm adapter Output zero Manual adjust via thumbwheel Cable length 2 m Operating temperature range 0°C to +50°C Storage temperature range (with battery removed) -20°C to +85°C Operating humidity 15% to 85% (non-condensing) Weight 250 g Safety standards BS EN 61010-1: 2001 BS EN 61010-2-032: 2002 BS EN 61010-031: 2002 300 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 300 V AC rms or DC and frequencies below 1 kHz EMC standards EN 61326: 1998 +A1, A2, and A3