Fluke v3000 FC Wireless AC Voltage Kit
The Fluke v3000 FC Wireless Voltage Kit is part of the Fluke Connect team of wireless test tools
Connect the v3000 FC Wireless AC Voltage Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.
You'll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect ™ modules as a system for multiple measurements.
From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless Temperature Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.
Now you can take readings on moving machinery, with only the measurement module in harm's way.
The Fluke FC Wireless v3000 Voltage Kit provides measurement of many common electrical parameters
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting:
- AC and DC voltage measurements to 1000 V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
With the Fluke v3000 FC Wireless AC Voltage Module you can:
- Measure up to 1000 V True-RMS AC
- Use as a standalone meter or as part of the system
- Use the logging function for recording and saving up to 65,000 readings
Fluke 3000 FC Wireless Digital Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).
Detailed Specifications AC Voltage Range 1 Resolution Accuracy 2 3 4 Accuracy 2 3 4 45 Hz to 500 Hz 500 Hz to 1 kHz 600.0 mV 0.1 mV 1.0% + 3 2.0% + 3 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.DC Voltage, Continuity, Resistance, Diode Test and Capacitance Function Range Resolution Accuracy mV 600.0 mV 0.1 mV 0.09% + 2 V 6.000 V 0.001 V 0.09% + 2 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 0.15% + 2 Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. Ω 600.0 Ω 0.1 Ω 0.5% + 2 6.000 kΩ 0.001 kΩ 0.5% + 1 60.00 kΩ 0.01 kΩ 60.00 kΩ 0.1 kΩ 600.0 kΩ 0.001 MΩ 50.00 MΩ 0.01 MΩ 1.5% + 3 Diode test 2.000 V 0.001 V 1% + 2 µF 1000 nF 1 nF 1.2% + 2 10.00 μF 0.01 μF 100.0 μF 0.1 μF 9999 μF1 1 μF 10% typical 1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. AC and DC Current Function Range 1 Resolution Accuracy mA AC
(45 Hz to 1 kHz)60.00 mA 0.01 mA 1.5% + 3 400.0 mA 3 0.1 mA mA DC 2 60.00 mA 0.01 mA 0.5% + 3 400.0 mA 3 0.1 mA 1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.Frequency Range Resolution Accuracy 1 99.99 Hz 0.01 Hz 0.1% + 1 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. Input Characteristics Function Overload
protectionInput impedance
(nominal)Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection