  1. Fluke 1555 10 kV Insulation Tester
special
special 2
Fluke 1555 10 kV Insulation Tester

Fluke 1555 10 kV Insulation Tester

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke 1555

Mejdaf part number 83-471

Availability: 5

21,805.15SAR 21,805.15SAR
Ex Tax: 18,961.00SAR
  • Description
  • Reviews (0)

Evaluate the trends, eliminate the doubt

The Fluke 1555 insulation resistance tester offers digital insulation testing up to 10 kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables.

Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1555 is the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.

Features include:

  • Test voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™
  • CAT III 1000 V, CAT IV 600 V safety rating
  • Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
  • Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
  • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
  • Long battery life gives the user over 750 tests between charges
  • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
  • Guard system eliminates the effect of surface leakage current on high-resistance measurements
  • Large digital/analog LCD for easy viewing
  • Capacitance and leakage current measurement
  • Ramp function for breakdown testing
  • Resistance measurements up to 2 TΩ
  • Timer settings up to 99 minutes for timed tests
  • 3-year warranty
  • Electrical Specifications
    The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ±.25% per °C, except on the 20% bands add ±1% per °C.
    Insulation Resistance Measurement
    Test voltage (DC)
    250 VRange< 250 kΩ,
    250 kΩ to 5 GΩ
    5 GΩ to 50 GΩ
    > 50 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    500 VRange< 500 kΩ
    500 kΩ to 10 GΩ
    10 GΩ to 100 GΩ
    > 100 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    1000 VRange< 1 MΩ
    1 MΩ to 20 GΩ
    20 GΩ to 200 GΩ
    > 200 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    2500 VRange< 2.5 MΩ
    2.5 MΩ to 50 GΩ
    50 GΩ to 500 GΩ
    > 500 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    5000 VRange< 5 MΩ
    5 MΩ to 100 GΩ
    100 GΩ to 1 TΩ 
    > 1 TΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    10000 VRange< 10 MΩ
    10 MΩ to 200 GΩ
    200 GΩ to 2 TΩ 
    > 2 TΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    Bar graph range0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)
    Insulation test voltage accuracy-0%, +10% at 1 mA load current
    Induced AC mains current rejection2 mA maximum
    Charging rate for capacitive load5 seconds per μF
    Discharge rate for capacitive load1.5 s/μF
    Leakage current measurementRange1 nA to 2 mA
    Accuracy±(5% + 2 nA)
    Capacitance measurementRange0.01 μF to 15.00 μF
    Accuracy±(15% rdg + 0.03 μF)
    TimerRange0 to 99 minutes
    Resolution setting1 minute
    Resolution indication1 second
    Live circuit warningWarning range30 V to 660 V AC/DC, 50/60 Hz
    Voltage accuracy±(15% + 2 V)
    Software specificationsFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
    General Specifications
    Display75 x 105 mm
    Power12 V lead-acid rechargeable battery, Yuasa NP2.8-12
    Charger Input (AC)85 V to 250 V AC 50/60 Hz 20 VA
    This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
    Dimensions269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
    Weight3.7 kg (8.2 lb)
    Temperature (operating)-20°C to 50°C (-4°F to 122°F)
    Temperature (storage)-20°C to 65°C (-4°F to 149°F)
    Humidity80% to 31°C decreasing linearly to 50% at 50°C
    Altitude2000 m
    Enclosure sealingIP40
    Input overload protection1000 V AC
    Electromagnetic compatibilityEN 61326
    Safety complianceIEC 61010-1: Overvoltage category II, Pollution Degree 2. 
    IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
    IEC 61557-1, IEC 61557-2
    Fluke 1555 and 1550C Insulation Resistance TestersDownload

Write a review

Note: HTML is not translated!
    Bad           Good


Information
  • About Us
  • Delivery and Returns
  • Privacy Policy
  • Terms & Conditions
  • Advertise with Us
Customer Service
  • Contact Us
  • Returns
  • Site Map
  • Gift Vouchers
Extras
  • Brands
  • Gift Vouchers
  • Specials
My Account
  • My Account
  • Order History
  • Wish List
  • Newsletter
Contact Us
  •  Anas Bin Malek Rd., Riyadh, KSA
  •  Phone: (+966) 114 192 112
  •  Email: Support@mejdaf.com
Newsletter
Staying in Touch
Top
Mejdaf for Information Technology © 2025. All Rights Reserved Mejdaf.com