  1. Electrical Measurements
  2. Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit
special
special 2
Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit

Fluke v3003 FC Wireless AC-DC Voltage Measurement Kit

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke v3003 FC Kit

Availability: On Request

5,853.50SAR 5,853.50SAR
Ex Tax: 5,090.00SAR
  • Description
  • Reviews (0)
  • The FC Wireless v3003 AC-DC Voltage Measurement Kit is part of the Fluke Connect team of wireless test tools

    Connect the v3000 FC Wireless AC Voltage and v3001 FC Wireless DC Voltage Modules to your test points, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

    You'll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect ™ modules as a system for multiple measurements.

    From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless Voltage Modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

    Now you can take readings on moving machinery, with only the measurement module in harm's way.

  • The Fluke FC Wireless v3003 AC-DC Voltage Measurement Kit

    The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting:

    • AC and DC voltage measurements to 1000V
    • AC and DC current with 0.01 mA resolution
    • Continuity, resistance, diode test, capacitance and frequency measurements
    • MIN/MAX recording
    • CAT III 1000 V, Cat IV 600 V; IP54

    With the Fluke v3000 FC Wireless AC Voltage Module you can:

    • Measure up to 1000 V True-RMS AC
    • Use as a standalone meter or as part of the system
    • Use the logging function for recording and saving up to 65,000 readings

    The Fluke v3001 FC Wireless DC Voltage Module lets you:

    • Measure up to 1000 V DC
    • Use as a standalone meter or as part of the system
    • Use the logging function for recording and saving up to 65,000 readings
  • Fluke 3000 FC Wireless Digital Multimeter

    * For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [ Number of least significant digits ]).

    Detailed Specifications
    AC Voltage
    Range 1ResolutionAccuracy 2 3 4Accuracy 2 3 4
    45 Hz to 500 Hz500 Hz to 1 kHz
    600.0 mV0.1 mV1.0% + 32.0% + 3
    6.000 V0.001 V
    60.00 V0.01 V
    600.0 V0.1 V
    1000 V1 V
    1. All AC voltage ranges are specified from 1% of range to 100% of range. 
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. 
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    FunctionRangeResolutionAccuracy
    mV600.0 mV0.1 mV0.09% + 2
    V6.000 V0.001 V0.09% + 2
    60.00 V0.01 V
    600.0 V0.1 V
    1000 V1 V0.15% + 2
    Ω600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω600.0 Ω0.1 Ω0.5% + 2
    6.000 kΩ0.001 kΩ0.5% + 1
    60.00 kΩ0.01 kΩ
    60.00 kΩ0.1 kΩ
    600.0 kΩ0.001 MΩ
    50.00 MΩ0.01 MΩ1.5% + 3
    Diode test2.000 V0.001 V1% + 2
    µF1000 nF1 nF1.2% + 2
    10.00 μF0.01 μF
    100.0 μF0.1 μF
    9999 μF11 μF10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    FunctionRange 1ResolutionAccuracy
    mA AC 
    (45 Hz to 1 kHz)
    60.00 mA0.01 mA1.5% + 3
    400.0 mA 30.1 mA
    mA DC 260.00 mA0.01 mA0.5% + 3
    400.0 mA 30.1 mA
    1. All AC current ranges are specified from 5% of range to 100% of range. 
    2. Input burden voltage (typical): 400 mA input 2 mV/mA. 
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    RangeResolutionAccuracy 1
    99.99 Hz0.01 Hz0.1% + 1
    999.9 Hz0.1 Hz
    9.999 kHz0.001 kHz
    99.99 kHz0.01 kHz
    1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    FunctionOverload 
    protection
    Input impedance 
    (nominal)
    Common mode reject

    Write a review

    Note: HTML is not translated!
        Bad           Good


    Information
    • About Us
    • Delivery and Returns
    • Privacy Policy
    • Terms & Conditions
    • Advertise with Us
    Customer Service
    • Contact Us
    • Returns
    • Site Map
    • Gift Vouchers
    Extras
    • Brands
    • Gift Vouchers
    • Specials
    My Account
    • My Account
    • Order History
    • Wish List
    • Newsletter
    Contact Us
    •  Anas Bin Malek Rd., Riyadh, KSA
    •  Phone: (+966) 114 192 112
    •  Email: Support@mejdaf.com
    Newsletter
    Staying in Touch
    Top
    Mejdaf for Information Technology © 2023. All Rights Reserved Mejdaf.com