  1. Electrical Measurements
  2. Fluke 87V/E2 Industrial Electrician Combo Kit
special
special 2
Fluke 87V/E2 Industrial Electrician Combo Kit

Fluke 87V/E2 Industrial Electrician Combo Kit

0 reviews | Write a review

Brand: FLUKE

Product Code: 87-V/E2K

Mejdaf part number 83-030

Availability: 1

3,820.30SAR 3,820.30SAR
Ex Tax: 3,322.00SAR
  • Description
  • Reviews (0)

This combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world, and includes special accessories to make you even more productive on the job. This kit will save over 15% compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.

    • Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
    • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
    • Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
    • Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models
    • True-rms ac voltage and current for accurate measurements on non linear signals
    • Selectable filter for accurate voltage and frequency measurements on motor drives
    • 0.05% DC accuracy
    • 6000 counts, 3-3/4 digits
    • 4-1/2 digit mode for precise measurements (20,000 counts)
    • Measure up to 1000 V AC and DC
    • Measure up to 10 A, 20 A for up to 30 seconds
    • Built in thermometer lets you carry one less tool (TC probe included)
    • Frequency to 200 kHz and % duty cycle
    • Resistance, continuity and diode test
    • 10,000 µF capacitance range for components and motor caps
    • Min/Max-Average recording with Min/Max Alert to capture variations automatically
    • Peak capture to record transients as fast as 250 µs
    • Relative mode to remove test lead interference from low ohms measurements
    • Auto and manual ranging for maximum flexibility
    • Touch Hold to capture stable readings avoiding noisy signals
    • Large display digits and two-level bright white backlight for increased visibility
    • Analog bargraph for fast changing or unstable signals
    • Input Alert provides audible warning against wrong use of input jacks
    • Improved selectable sleep mode for long battery life
    • Access door for fast battery changes without breaking the calibration seal
    • "Classic" design with new removable holster with built in test lead and probe storage
    • Lifetime warranty

    87V_10

    Electrical safety

    All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.

    Correctly measure pulse-width modulated motor drive signals

    Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.

    • Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
    • Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
    • Measure AC current with an optional current clamp accessory
    • Compare reading from the 87V with the display on the ASD
    • Special shielding blocks high frequency, high-energy noise generated by large drive systems

     

     
    Complex PWM drive signals are not a problem for the Fluke 87V. Pulse-width modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 micro-second pulses can cause erratic behavior in some test equipment.
    • Specifications
      Voltage DCMaximum Voltage1000 V
      Accuracy±(0.05% + 1)
      Maximum Resolution10 µV
      Voltage ACMaximum Voltage1000 V
      Accuracy±(0.7% + 2) True RMS
      AC Bandwidth20 kHz with low pass filter; 3 db @ 1 kHz
      Maximum Resolution0.1 mV
      Current DCMaximum Amps10 A (20 A for 30 seconds maximum)
      Amps Accuracy±(0.2% + 2)
      Maximum Resolution0.01 µA
      Current ACMaximum Amps10 A (20 A for 30 seconds maximum)
      Amps Accuracy±(1.0% + 2) True RMS
      Maximum Resolution0.1 µA
      ResistanceMaximum Resistance50 MΩ
      Accuracy±(0.2% + 1)
      Maximum Resolution0.1Ω
      CapacitanceMaximum Capacitance9,999 µF
      Accuracy±(1% + 2)
      Maximum Resolution0.01 nF
      FrequencyMaximum Frequency200 kHz
      Accuracy±(0.005% + 1)
      Maximum Resolution0.01 Hz
      Duty CycleMaximum Duty Cycle99.9%
      Accuracy±(0.2% per khz +0.1%)
      Maximum Resolution0.1%
      Temperature Measurement-200.0°C - 1090°C
      -328.0°F - 1994.0°F
      excluding probe
      80 BK Temperature Probe-40.0°C - 260°C
      -40.0°F - 500°F, 2.2°C or 2% whichever is greater
      ConductanceMaximum Conductance60.00 nS
      Accuracy±(1.0% + 10)
      Maximum Resolution0.01 nS
      DiodeRange3 V
      Resolution1 mV
      Accuracy±(2% + 1)
      Duty Cycle RangeAccuracyWithin ±(02% per kHz +0.1%)
      Environmental Specifications
      Operating Temperature-20°C to +55°C
      Storage Temperature-40°C to +60°C
      Humidity (Without Condensation)0% - 90% (0°C - 35°C)
      0% - 70% (35°C - 55°C)
      Operating Altitude2000 m
      Safety Specifications
      Overvoltage categoryEN 61010-1 to 1000 V CAT III, 600V CAT IV
      Agency ApprovalsUL, CSA, TÜV, VDE listed
      Mechanical and General Specifications
      Size201 x 98 x 52 mm (with holster)
      Weight355 g
      624 g - with holster
      DisplayDigital6000 counts updates 4/sec.
      19,999 counts in high-resolution mode
      Analog32 segments, updates 40/sec.
      Frequency19,999 counts, updates 3/sec at > 10 Hz
      Warranty

      Write a review

      Note: HTML is not translated!
          Bad           Good


      Information
      • About Us
      • Delivery and Returns
      • Privacy Policy
      • Terms & Conditions
      • Advertise with Us
      Customer Service
      • Contact Us
      • Returns
      • Site Map
      • Gift Vouchers
      Extras
      • Brands
      • Gift Vouchers
      • Specials
      My Account
      • My Account
      • Order History
      • Wish List
      • Newsletter
      Contact Us
      •  Anas Bin Malek Rd., Riyadh, KSA
      •  Phone: (+966) 114 192 112
      •  Email: Support@mejdaf.com
      Newsletter
      Staying in Touch
      Top
      Mejdaf for Information Technology © 2023. All Rights Reserved Mejdaf.com