Fluke 43B Single Phase Power Quality Analyzer
22,159.35SAR
22,159.35SAR
Ex Tax: 19,269.00SAR
Get control of power problems
The Fluke 43B has been the go-to industry leading single phase analyzer for over a decade in both industrial and classroom settings because of its intuitive ease of use and overall simplicity in performing just the right the measurements that you need to maintain power systems and troubleshoot power problems and diagnose equipment failures.
- NiMH Battery provides extended operating time of 6.5 hours
- Combines the most useful capabilities of a power quality analyzer, multimeter and scope
- Calculates 3-phase power on balanced loads, from a single-phase measurement
- Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current
- Monitoring functions help track intermittent problems and power system performance
- Records two selectable parameters for up to 16 days
- 20 measurement memories to save/recall screens and data with cursor readings
- FlukeView® software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic
- Measures resistance, diode voltage drop, continuity, and capacitance
- Users/applications manual and power quality video to help answer tough questions
- Complete package with voltage probes and 400 A current clamp, FlukeView Software and optically isolated interface cable
- 3 year warranty on the Fluke 43B, 1 year on accessories
Specifications | |||
Input characteristics | Input impedance | 1 MΩ, 20 pF | |
Voltage rating | 600 V rms, CAT III | ||
V/A/Hz display | True-rms voltage (AC + DC) | Ranges | 5.000 V, 50.00 V, 500.0 V, 1250 V1 |
Accuracy | ±(1% + 10 counts) | ||
True-rms current (AC + DC) | Ranges | 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA | |
Accuracy | ±(1% + 10 counts) | ||
Frequency | Ranges | 10.0 to 15.0 kHz | |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
CF crest factor | Ranges | 1.0 - 10.0 | |
Accuracy | ±(5% + 1 count) | ||
Power display | Watts, VA, VAR | 1-phase and 3-phase,3 conductor balanced loads | |
Ranges | 250 W - 1.56 GW | ||
Accuracy | ±(4% + 4 counts) Fundamental Power | ||
Accuracy | ± (2% + 6 counts) Total Power | ||
PF power factor | Range | 0 - 1.0 | |
Accuracy | ±0.04 | ||
DPF displacement power factor, Cos .F | Range | 0.25 - 0.9 | |
Accuracy | ±0.04 | ||
Range | 0.90 - 1.0 | ||
Accuracy | ±0.03 | ||
H2 frequency fundamental | Ranges | 40.0 to 70.0 Hz | |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
Harmonics display | Voltage, current, frequency | Ranges | Fundamental to 51st harmonic |
Accuracy | VA ±(3% + 2 counts) W ±(5% + 2 counts) | ||
Fundamental | 2 to 31st harmonic | VA ±(5% +3 counts) W ±(10% +10 counts) | |
32 to 51st harmonic | VA ±(15% +5 counts) W ±(30% +5 counts) | ||
Frequency fundamental | Ranges | 40 Hz to 70 Hz | |
Accuracy | ±0.25 Hz | ||
Phase | Range | V, A (Between fundamental and harmonics) | |
Accuracy | ±3° to ±15° | ||
Range | W (Between voltage fundamental and current harmonics) | ||
Accuracy | ±5° to ±15° | ||
K-factor (Current and Power) | Range | 1.0 to 30.0 | |
Accuracy | ±10% | ||
THD total harmonic distortion | Range | 0.00 - 99.99 | |
Accuracy | ±(3% + 8 counts) | ||
Sags and swells | Recording times | 4 min to 16 days (selectable) | |
Vrms actual, vrms max, min (AC + DC) | Ranges | 5.000 V, 50.00 V, 500.0 V, 1250 V1 | |
Accuracy | Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts) | ||
Arms actual, arms max, min (AC + DC) | Ranges | 50.00 A, 500.0 A, 5.000 kA, 50.00 kA | |
Accuracy | ±(2% +10 counts) | ||
Transient capture | Minimum pulse width | 40 ns | |
Useful bandwidth input 1 | DC to 1 MHz | ||
Number of transients | 40 | ||
Voltage threshold settings | 20%, 50%, 100%, 200% above or below reference | ||
Reference signal | After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting. | ||
Vpeak min, vpeak max at cursor | 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale | ||
R, C, diode, continuity | Resistance ranges | 500.0 Ω, 5.000 kΩ, 50.00 kΩ, 500.0 kΩ, 5.000 MΩ, 30.00 MΩ | |
Resistance accuracy | ±(0.6% + 5 counts) | ||
Capacitance ranges | 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF | ||
Capacitance accuracy | ±(2% + 10 counts) | ||
Diode Ranges | 0 to 3.000 V | ||
Diode voltage | |||
Accuracy |
|