  • About us
Fluke 1760TR Three-Phase Power Quality Recorder

Fluke 1760TR Three-Phase Power Quality Recorder

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke 1760TR

Availability: On Request

126,477.00SAR 126,477.00SAR
Ex Tax: 109,980.00SAR
  • Description
  • Reviews (0)

Class-A compliance for the most demanding power quality tests

The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and low-voltage networks, this power quality monitor provides the flexibility to customize thresholds, algorithms, and measurement selections. The 1760 power recorder captures the most comprehensive details on user-selected parameters.

Applications

  • Detailed disturbance analysis – Perform high-speed transient analysis and uncover root cause of equipment malfunction for later mitigation and predictive maintenance. The fast transient option, with its 6000 V measurement range, allows capture of very short impulses such as lightning strikes.
  • Class-A quality-of-service compliance – Validate incoming power quality at the service entrance. Thanks to Class A compliance, the Fluke 1760 allows undisputable verification.
  • Event correlation at multiple locations – Utilizing GPS time synchronization, users can quickly detect where a fault occurred first, either inside or outside the facility.
  • Galvanic separation and DC coupling – Allows complete measurements on dissimilar power systems. For example troubleshoot UPS systems by simultaneously recording the battery voltage and power output.
  • Power quality and power load studies – Assess baseline power quality to validate compatibility with critical systems before installation and verify electrical system capacity before adding loads.
    • Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
    • GPS time synchronization: Correlate data with events or datasets from other instruments with precision
    • Flexible and fully configurable thresholds and scale factors: Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.
    • Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages to help determine the cause
    • 10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
    • 2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
    • Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
    • Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries
    • Rugged field design: Insulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions

    Features:

    • Power quality statistics according to EN50160
    • Voltage event list (dips, swells and interruptions)
    • Continuous recording of:
      • Voltage
      • Current
      • Power P, Q, S
      • Power factor
      • kWh
      • Flicker
      • Unbalance
      • Frequency
      • Voltage and current harmonics to the 50th / Interharmonics
      • THD
      • Mains signaling
    • Triggered recordings
    • Online mode (Oscilloscope, transients and events)
    • Fast transient analysis up to 10 MHz
    • 4, 600 V voltage probes
    • 4 dual-range flexible current probes (1000 A / 200 A AC)
    • GPS time sync receiver
    • 2 GB Flash Memory
  • Overview of Measurement Functions
    Statistical evaluationPower quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI
    Event listDips, swells and interruptions are detected and stored in the event list. Also any trigger which fires generates an event added to this list.
    The Event list shows the exact time when the event occurred as well as the duration and magnitude. Sorting by several attributes of these events is possible to select one for further root cause analysis.
    RMS values, transients and fast transients can be stored if a trigger fires
    Continuous recordingFluke 1760 records rms values together with corresponding minimum and maximum values for:
    • Voltage
    • Current
    • Power P, Q, S
    • Power Factor
    • kWh
    • Flicker
    • Unbalance
    • Frequency
    • Harmonics/Interharmonics continuously with the following time aggregations: Day, 10 min, Free Interval, e.g.: 15 min, 2 h<
    Triggered recordingsrmsAggregation time is adjustable between 10 ms (1/2 cycle), 20 ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles).
    Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency.
    Basic aggregation for harmonics and interharmonics is 200ms
    OscilloscopeSample rate is 10.24 kHz for all 8 channels
    Fast TransientsSample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients
    Mains signallingPhases and N-conductor, Voltage and current
    Online modeVariable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events.
    General Data
    Intrinsic uncertaintyrefers to reference conditions and is guaranteed for two years
    Quality systemdeveloped, manufactured as per ISO 9001: 2000
    Environment conditionsOperating temp. range0°C to +50°C; 32°F to +122°F
    Working temp. range-20°C to +50°C; -4°F to +122°F
    Storage temp. range20°C to +60°C; -4°F to 140°F
    Reference temperature23°C ±2 K; 74°F ±2 K
    Climatic classB2 (IEC 654-1), -20°C to +50°C; -4°F to +122°F
    Max. operating altitude2000 m: max. 600 V CAT IV1, power supply: 300 V CAT III 5000 m: max 600 V CAT III1, power supply: 300 V CAT II
    1. Depending on sensor
    Reference conditionsEnvironment temperature23°C ±2 K ; 74°F ±2 K
    Power supply230 V ±10%
    Power frequency50 Hz / 60 Hz
    Signaldeclared input voltage Udin
    Averaging10 minute intervals
    HousingInsulated, robust plastics housing
    EMCEmissionClass-A as per IEC/EN 61326-1
    ImmunityIEC/EN 61326-1
    Power supplyRangeAC: 83 V to 264 V, 45 to 65 Hz
    DC: 100 V to 375 V
    SafetyIEC/EN 61010-1 2nd edition
    300 V CAT III
    Power consumptionNIMH, 7.2 V, 2.7 Ah
    Battery packIn case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user.
    DisplayFluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer.
    Power LED
    • Permanent light: normal power supply from mains.
    • OFF: supply via internal accumulator in case of a power failure.
    Channel LEDs 3-color LEDs per channel for
    • overload condition
    • under load condition
    Data memory2 GB Flash memory
    Memory modelLinear
    InterfacesEthernet (100 MB/s), compatible to Windows® XP, 7 and 8, RS 232, external modem via RS 232
    Baud rate for RS 2329600 Baud to 115 kBaud
    Dimensions (H x W x D)325 x 300 x 65 mm; 2.8 x 11.8 x 2.6 in
    Weightappr. 4.9 kg; 10.8 lbs. (without accessories)
    Warranty2 years
    Calibration interval1 year recommended for Class-A, otherwise 2 years
    Signal Conditioning
    Range for 50 Hz systems50 Hz ±15% (42.5 Hz to 57.5 Hz)
    Range for 60 Hz systems60 Hz ±15% (51 Hz to 69 Hz)
    Resolution16 ppm