  1. Fluke 1550C 5 kV Insulation Tester
special
special 2
Fluke 1550C 5 kV Insulation Tester

Fluke 1550C 5 kV Insulation Tester

0 reviews | Write a review

Brand: FLUKE

Product Code: Fluke 1550C

Mejdaf part number 83-467

Availability: 1

18,520.75SAR 18,520.75SAR
Ex Tax: 16,105.00SAR
  • Description
  • Reviews (0)

Fluke 1550C 5 kV Insulation Tester
Includes:

Test cables with alligator clips (red, black, green)
Infrared adapter with interface cable
AC power cord
Soft carrying case
English manual
User's manual on CD-ROM
Quick reference card
Software license agreement
Registration card
USB-IR cable installation guide

The Fluke 1550C insulation resistance tester offers digital insulation testing up to 5 kV, making them ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables.

Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1550C is the perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.

  • Features include:

    • Test voltages to up 5 kV and save time by trending on the spot only with Fluke Connect™
    • CAT III 1000 V, CAT IV 600 V safety rating
    • Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
    • Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
    • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
    • Long battery life gives the user over 750 tests between charges
    • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
    • Guard system eliminates the effect of surface leakage current on high-resistance measurements
    • Large digital/analog LCD for easy viewing
    • Capacitance and leakage current measurement
    • Ramp function for breakdown testing
    • Resistance measurements up to 2 TΩ
    • Timer settings up to 99 minutes for timed tests
    • 3-year warranty
  • Electrical Specifications
    The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C.
    Insulation Resistance Measurement
    Test voltage (DC)
    250 VRange< 250 kΩ,
    250 kΩ to 5 GΩ
    5 GΩ to 50 GΩ
    > 50 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    500 VRange< 500 kΩ
    500 kΩ to 10 GΩ
    10 GΩ to 100 GΩ
    > 100 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    1000 VRange< 1 MΩ
    1 MΩ to 20 GΩ
    20 GΩ to 200 GΩ
    > 200 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    2500 VRange< 2.5 MΩ
    2.5 MΩ to 50 GΩ
    50 GΩ to 500 GΩ
    > 500 GΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    5000 VRange< 5 MΩ
    5 MΩ to 100 GΩ
    100 GΩ to 1 TΩ 
    > 1 TΩ
    Accuracy (± reading)Unspecified
    5%
    20%
    Unspecified
    Bar graph range0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)
    Insulation test voltage accuracy-0%, +10% at 1 mA load current
    Induced AC mains current rejection2 mA maximum
    Charging rate for capacitive load5 seconds per μF
    Discharge rate for capacitive load1.5 s/μF
    Leakage current measurementRange1 nA to 2 mA
    Accuracy± (5% + 2 nA)
    Capacitance measurementRange0.01 μF to 15.00 μF
    Accuracy± (15% rdg + 0.03 μF)
    TimerRange0 to 99 minutes
    Resolution setting1 minute
    Resolution indication1 second
    Live circuit warningWarning range30 V to 660 V AC/DC, 50/60 Hz
    Voltage accuracy± (15% + 2 V)
    Software specificationsFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
    General Specifications
    Display75 x 105 mm
    Power12 V lead-acid rechargeable battery, Yuasa NP2.8-12
    Charger Input (AC)85 V to 250 V AC 50/60 Hz 20 VA
    This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
    Dimensions269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
    Weight3.7 kg (8.2 lb)
    Temperature (operating)-20°C to 50°C (-4°F to 122°F)
    Temperature (storage)-20°C to 65°C (-4°F to 149°F)
    Humidity80% to 31°C decreasing linearly to 50% at 50°C
    Altitude2000 m
    Enclosure sealingIP40
    Input overload protection1000 V AC
    Electromagnetic compatibilityEN 61326
    Safety complianceIEC 61010-1: Overvoltage category II, Pollution Degree 2. 
    IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
    IEC 61557-1, IEC 61557-2
    Fluke 1555 and 1550C Insulation Resistance TestersDownload

Write a review

Note: HTML is not translated!
    Bad           Good


Information
  • About Us
  • Delivery and Returns
  • Privacy Policy
  • Terms & Conditions
  • Advertise with Us
Customer Service
  • Contact Us
  • Returns
  • Site Map
  • Gift Vouchers
Extras
  • Brands
  • Gift Vouchers
  • Specials
My Account
  • My Account
  • Order History
  • Wish List
  • Newsletter
Contact Us
  •  Anas Bin Malek Rd., Riyadh, KSA
  •  Phone: (+966) 114 192 112
  •  Email: Support@mejdaf.com
Newsletter
Staying in Touch
Top
Mejdaf for Information Technology © 2025. All Rights Reserved Mejdaf.com